MSLBA23PLUS
Overall Performance
Equipment type        Fully automatic discrete, STAT priority
Analysis rate          Constant speed 200T/H (without ISE)
Test principle          Colorimetry, turbidimetry
Analysis method       End-point, 2 kinetics, fixed-time, etc. support single/double wavelength, linear and non-linear calibration
Sample System
Sample Tray          42 sample positions, random access of all samples
Sample Volume       2-50ul, 0.1ul increment
Sample probe         Liquid level detection, the remaining detection, collision protection etc.
Sample Containers    Sample cups, Micro tube, Original blood-collection tube, etc.
Reagent System
Reagent Tray         25 reagent positions
Reagent Volume      R1:25-300ul, R2:10-150ul, 0.1ul increment
Reagent Probe        Liquid level detection, the remaining detection, collision protection etc.
Reagent Refrigeration    4-15ºC, independent power supply, 24-hour non-stop refrigeration
Reaction System
Reaction Tray        Rotating tray, 120 cuvettes
Cuvette             Reusable high quality cuvette, Optical diameter 6mm
Reaction Volume     180-500ul
Incubation system    Bi-directional liquid-air device
Temperature         37ºC±0.1ºC with real-time display
Optical System
Light source           12V35W halogen lamps, over 2000 hours
Photoelectron road     after spectrophotometry
Wavelength           340,405,450,510,546,578,630,700nm
Absorbance range     0-3.500Abs
Resolution            0.0001Abs
Operating System
PC operating system       Windows XP or above
Analysis control software      English version graphical operating software
Report printing            Report formats support the user-defined mode, QC and state information etc.
System connection        RS-232
Working Conditions
Power supply             AC 220V±22V, 50Hz±1Hz, power 1.5KVA
Ambient Temperature     15-30 ºC
Humidity                 35-80%
Water consumption        5L/Hour
Dimension                Bench top: 750mm*520mm*600mm
Weight                   45KG
Â






MSLBA23PLUS
Overall Performance
Equipment type        Fully automatic discrete, STAT priority
Analysis rate          Constant speed 200T/H (without ISE)
Test principle          Colorimetry, turbidimetry
Analysis method       End-point, 2 kinetics, fixed-time, etc. support single/double wavelength, linear and non-linear calibration
Sample System
Sample Tray          42 sample positions, random access of all samples
Sample Volume       2-50ul, 0.1ul increment
Sample probe         Liquid level detection, the remaining detection, collision protection etc.
Sample Containers    Sample cups, Micro tube, Original blood-collection tube, etc.
Reagent System
Reagent Tray         25 reagent positions
Reagent Volume      R1:25-300ul, R2:10-150ul, 0.1ul increment
Reagent Probe        Liquid level detection, the remaining detection, collision protection etc.
Reagent Refrigeration    4-15ºC, independent power supply, 24-hour non-stop refrigeration
Reaction System
Reaction Tray        Rotating tray, 120 cuvettes
Cuvette             Reusable high quality cuvette, Optical diameter 6mm
Reaction Volume     180-500ul
Incubation system    Bi-directional liquid-air device
Temperature         37ºC±0.1ºC with real-time display
Optical System
Light source           12V35W halogen lamps, over 2000 hours
Photoelectron road     after spectrophotometry
Wavelength           340,405,450,510,546,578,630,700nm
Absorbance range     0-3.500Abs
Resolution            0.0001Abs
Operating System
PC operating system       Windows XP or above
Analysis control software      English version graphical operating software
Report printing            Report formats support the user-defined mode, QC and state information etc.
System connection        RS-232
Working Conditions
Power supply             AC 220V±22V, 50Hz±1Hz, power 1.5KVA
Ambient Temperature     15-30 ºC
Humidity                 35-80%
Water consumption        5L/Hour
Dimension                Bench top: 750mm*520mm*600mm
Weight                   45KG
Â
Dye Intermediate,a polycarbonate composition excellent in both antistatic property and coloring matter coatability containing (a) a polycarbonate obtained by an ester exchange process, and (b) a compound having a molecular weight of from 300 to 8,000 and having any of ester bond, carbonate bond, amide bond and urethane bond in its molecule and an aromatic hydrocarbon group substituted by at least one alkyl group at the molecular end thereof, a write once read many optical disc substrate and a write once read many optical discusing the same and a process for the production of a write once read many optical disc are described.